GSA PT 10

Rapid and easy measurements

Description

On point

Our GSA PT 10 product line is built upon the standard Linseis microbalance design. This highly sensitive microbalance comes in two versions, offering exceptional precision with a sensitivity of 0.1 or 1 microgram for sample weights of 5, 25, and 35 grams.

For versatile operation, we provide a range of environmental chambers, enabling testing across a wide temperature spectrum, from as low as -150°C to as high as 1600°C, and under ultra-high vacuum conditions up to 10 bar.

Additionally, you have the option to enhance the capabilities of the system with a TG-DSC (Thermogravimetry – Differential Scanning Calorimetry) measuring head. This feature allows for the simultaneous determination of weight changes and calorimetric reactions in a single test run. 

To further expand the system’s capabilities, we offer optional gas and vapor dosing systems, as well as residual gas analysis. This versatility enables you to work with a variety of vapors and gases, including alcohols, hydrocarbons, aromatics, hydrogen, water, oxygen, nitrogen, argon, carbon oxides, and more.

Specifications

Model GSA PT 10*
Temperature range:  -100°C up to 200°C
Sample mass: up to 5/25/35 g (higher sample weights on request)
Resolution: 0.025 / 0.1 μg
Vacuum: bis 10E-5 mbar
Pressure: bis 5/10 bar
Sensors: TG
TG – DTA
Sensor material: E/K/S/B
Electronic: integrated
Interface: USB

*Specs depend on configurations

Accessories

Software for Calculating DTA Signals:

We offer specialized software designed for the precise determination of DTA (Differential Thermal Analysis) signals, ensuring accurate and reliable results.

Various Vacuum and Turbo Molecular Pumps:

Our product range includes a selection of vacuum and turbo molecular pumps, catering to different applications and requirements. These pumps are engineered to provide optimal vacuum conditions and performance.

Choice of Gas Control Boxes:

We offer a comprehensive selection of gas control boxes, allowing you to choose between manual, semi-automatic, and automatic configurations with Mass Flow Controllers (MFC). These systems enable precise control over gas flow for your specific needs.

Wide Variety of Crucibles:

We provide a diverse range of crucibles, including options such as gold, silver, platinum, quartz glass, alumina oxide, aluminum, high-pressure stainless steel, and more. These crucibles are suitable for various sample types and testing conditions.

Multiple Measuring Systems:

Our product offerings encompass different measuring systems, each tailored to specific analytical requirements. These systems are designed to deliver accurate and detailed data for your thermal analysis needs.

Optional Evolved Gas Analysis (EGA):

For enhanced analytical capabilities, we offer optional Evolved Gas Analysis (EGA) features. This enables the concurrent analysis of gases evolving from your samples during thermal testing, providing valuable insights into chemical reactions and decomposition processes.

You are interested in a GSA PT 10?

You need more information?

Contact us today!

Software

All LINSEIS thermo-analytical instruments are designed to be seamlessly integrated with PC control. Our software modules exclusively operate on Microsoft® Windows® operating systems, ensuring compatibility and ease of use. The complete software comprises three key modules: temperature control, data acquisition, and data evaluation. This 32-bit software encompasses all essential functionalities for comprehensive measurement preparation, execution, and evaluation in a Simultaneous Thermal Analysis (STA) measurement.

TG (Thermogravimetry) Features:

  1. Measurement of mass change in both percentage and milligrams.
  2. Controlled mass loss rate.
  3. Evaluation of mass loss data.
  4. Assessment of residue mass.

General Features:

  1. Program functionality with text editing capabilities.
  2. Data security mechanisms in the event of a power failure.
  3. Protection against thermocouple breakage.
  4. Repetition of measurements with minimal parameter input.
  5. Real-time evaluation of the ongoing measurement.
  6. Comparative analysis of up to 32 curves.
  7. Storage and export options for evaluations.
  8. Import and export of data in ASCII format.
  9. Seamless data export to Microsoft Excel.
  10. Support for multi-methods analysis, including DSC, TG, TMA, DIL, and more.
  11. Zoom function for detailed analysis.
  12. First and second derivative calculations.
  13. Programmable gas control for precise experimental conditions.
  14. Statistical evaluation package for comprehensive data analysis.
  15. Free scaling capabilities for versatile data representation.

Applications

Application Areas
  • Gas Sorption Analysis
  • Sorption Enthalpies (Simultaneous TG/DSC-Sensor)
  • Density Determination
  • Gas Storage
  • Zeolites
  • Catalysts
  • In-situ Gas Analysis (FTIR, Raman, ELIF)
  • Kinetic Analysis
  • Corrosive Atmospheres – Magnetic Suspension Balance
  • Adsorption Isotherms (BET Surface Analysis)
  • TPD, TPO, TPR measurements (-196 to 1800 °C)
Application example: Desorption of Hydrogen of TiH2

Downloads

GSA Product Brochure (PDF)

Scroll to Top